Standard Configuration
A custom MW100 measuring system is comprised of three elements; the MW100 main module, MX Series input/output modules, and MX150 Series base plate. The system can be bench mounted as-is or DIN rail mounted for rack or panel installations. A DIN rail-mounting bracket is included with the MX150.
The input/output modules, base plate, and accessories are all the same as those for the MX100 DAQMASTER series (AC adapter is for the MW100 only).
Name |
Model |
Number of Channels | Shortest Measurement Interval | Description |
10 channel pulse input module | MX114-PLS-M10 | 10 |
100 ms |
Non-voltage contact /Open collector(10,000 sample/sec integration speed) |
30 ch general purpose input module 500 ms scan speed | MX110-VTDL30 |
30 |
500 ms |
Clamp terminal, DCV/TC/DI |
MX110-VTDL30/H3 | 30 |
500 ms |
M3 screw terminal, DCV/TC/DI |
Name |
Model |
Number of Channels |
Shortest Measurement Interval |
Description |
Universal Input Modules |
MX110-UNV-H04 |
4 |
10 ms |
DC voltage, thermocouple, 3-wire RTD, DI (non-voltage contact, Level (5 V logic). Mixed input allowed. |
MX110-UNV-M10 |
10 |
100 ms |
DC voltage, thermocouple, 3-wire RTD, DI (non-voltage contact, Level (5 V logic). Mixed input allowed. |
|
4 Wire RTD and Resistance Input Module |
MX110-V4R-M06 |
6 |
100 ms |
DC voltage, 4-wire RTD, 4-wire resistance, DI (non-voltage contact, Level (5 V logic). Mixed input allowed. |
Strain Input Modules |
MX110-B12-M04 |
4 |
100 ms |
Built-in bridge resistance of 120 ohm |
MX112-B35-M04 |
Built-in bridge resistance of 350 ohm |
|||
MX112-NDI-M04 |
For connection with an external bridge head and strain gauge type sensor (NDIS connector). |
|||
5 V Digital Input Module |
MX115-D05-H10 |
10 |
10 ms |
Non-voltage contact, open collector, and Level (5 V logic). Mixed input allowed. |
24 V Digital Input Module |
MX115-D24-H10 |
10 |
10 ms |
Level (24 V logic), Vth = 12 V |
Name |
Model |
Number of Channels | Output Update Interval | Description |
Analog Output Module | MX120-VAO-M08 | 8 | 100 ms | Allows mixed voltage (±10 V) and current (4-20 mA) output |
PWM Output Module | MX120-PWM-M08 | 8 | 100 ms |
Pulse width modulation output module |
Digital Output Module | MX125-MkC-M10 | 10 | 100 ms |
“A” contact (SPST) |
![]() |
Base plates available for all configurations, from 1 to 6 input/output modules.
When used for the MW100/MX100, you must replace the attachment with the one that comes standard with the MW100/MX100.
|
![]() |
Connector Covers Connector covers for open slots AC Adapter (772075) AC adapter for the DC power model. Operating temperature range: 0 to 40° *Only for the MW100 |
![]() |
All input/output terminals are removable except for those of the MX112-NDI-M04. If multiple terminals are prepared ahead of time, no re-wiring is needed between measurements. |
![]() |
Model | Description |
772061 |
Screw (M4) terminal block (RJC (reference junction compensation) included). For use in combination with 772062. Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10. |
772062 |
Connection cable between input modules and the screw terminal block. Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10. |
772063 |
Plate with clamp terminals (RJC included). Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10. |
772064 |
Clamp terminals. Compatible with MX110-UNV-H04. |
772065 | Clamp terminals. Compatible with MX120-VAO-M08, MX120-PWM-M08, and MX125-MKC-M10. |
772067 |
Plate with clamp terminals. Compatible with MX110-V4R-M06. |
772068 |
Plate with clamp terminals (Built-in bridge resistance of 120 ohm). Compatible with MX112-Bxx-M04. |
772069 |
Plate with clamp terminals (Built-in bridge resistance of 350 ohm). Compatible with MX112-Bxx-M04. |
772080 |
Plate with screw (M3) terminal (RJC included). Compatible with MX110-UNV-M10, MX115-D05-H10, and MX115-D24-H10. |
772081 |
Plate with clamp terminal for current with 10 ohm built in bridge resistance, applies to MX110-UNV-M10 |
772082 |
Plate with clamp terminal for current with 100 ohm built in bridge resistance, applies to MX110-UNV-M10 |
772083 |
Plate with clamp terminal for current with 250 ohm built in bridge resistance, applies to MX110-UNV-M10 |
Measurement Information Shared![]() |
Measured Data Shared![]() * Mail Server Required |
![]() |
A large data acquisition system of up to 360 channels can be assembled using multiple MW100s and standard MODBUS TCP Ethernet communications. When equipped with the /M1 math option, the MW100 can acquire up to 300 channels of external data from additional MW100 units or other devices such as a PLC using MODBUS TCP communications. This provides a total system capacity of 360 channels (60 built-in measure channels + 300 external).
|
Serial MODBUS RTU communications (RS- 232 or RS-422A/485) can be ordered as a separate option with the same capability. |
![]() |
An optional serial MODBUS RTU interface provides data exchange functions with other devices such as recorders, PLCs and controllers. In this mode, MW100 can serve as expansion I/O or as a data acquisition terminal for another connected device. |
![]() Screen updating may be slower depending on the communication environment. |
When the measurement location is located remotely from the data monitoring station, a dial up phone connection can be used for communications. All MW100 web browser-based data monitoring and FTP functions can be used via this connection for remote data acquisition applications. |
![]() |
The MW100 can synchronize its clock to a network time-server using SNTP (Simple Network Time Protocol), allowing any number of MW100s in a system to have precisely matched time.
Both SNTP Server and Client modes are supported. In Server mode, one MW100 can acquire time data from a server using Client mode. It can then serve time data in Server mode to other MW100s that function as Clients. Clock synchronization functions are allowed only when the measurement interval within the unit is two seconds or longer.
|